Hot gas reheat coil replacement

A hot gas reheat coil sits downstream of the DX evaporator and uses hot refrigerant gas from the compressor to warm overcooled air back to a comfortable supply temperature. It is how many rooftop units and dedicated outdoor air units control humidity. We match replacements to the unit and its reheat circuit.

Automated hairpin bender forming copper tube

When it is time to replace

Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.

  • Refrigerant leaks

    Leaks in the reheat coil, often found while chasing a low charge.

  • Humidity complaints

    Clammy spaces or cold supply air when dehumidification is running.

  • Corroded fins

    Fin and tube damage similar to the evaporator just upstream.

  • Evaporator replacement

    The reheat coil often sits in the same casing; check it when the evaporator is replaced.

What we confirm before we quote

You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

Automated hairpin bender forming copper tube
AFin height
Finned area inside the casing.
BFin length
Finned length between tube sheets.
Rows and fins per inch
Usually one or two rows.
Refrigerant
The refrigerant in the system now.
JConnections
Hot gas inlet and liquid outlet size and location.
Position
Where the coil sits relative to the evaporator, and whether they share a casing.
Performance
Airflow, entering air conditions and the reheat you need.

Request a quote Measuring worksheets

Built in America.
Rated. Tested.

Flag of the United States

Built in American plants

Our manufacturing partners’ plants are located in:

  • Oklahoma City, OK
  • Okarche, OK
  • Moscow, TN
  • Phoenix, AZ
  • Tampa Bay, FL
  • Fort Worth, TX
AHRI Certified

AHRI 410 rated selections

Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.

100%Leak tested

Leak tested under water

Every coil is pressurized and leak tested under water before it leaves the plant.

Copper hairpin tubes being laced through aluminum fins on a coil line

Construction notes

Reheat coils usually mount directly behind the evaporator, sometimes in the same casing. If the evaporator is being replaced, it is worth checking the reheat coil at the same time.

Modulating and on/off reheat systems are piped differently. Tell us how the reheat valve is controlled so the replacement suits the circuit.

Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.

Frequently asked questions

What does a hot gas reheat coil do?

It sits downstream of the DX evaporator and uses hot refrigerant gas from the compressor to warm overcooled air back to a comfortable supply temperature. It is how many rooftop units and dedicated outdoor air units control humidity.

Can the reheat coil be replaced without the evaporator?

Often, if it can be removed on its own. Where the two share a casing, replacing both together can save a second trip.

What do you need to quote a reheat coil?

Fin height and length, rows and fins per inch, the refrigerant, the hot gas and liquid connections, and where the coil sits relative to the evaporator.

Does it matter how the reheat is controlled?

Yes. Modulating and on/off reheat systems are piped differently, so tell us how the reheat valve is controlled.

Replacing a hot gas reheat coil?

Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.