DX evaporator coil replacement
Direct expansion coils cool air by evaporating refrigerant inside the tubes. A replacement has to match more than size: circuiting, the distributor and the number of refrigerant circuits all have to suit the condensing unit it works with.


When it is time to replace
Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.
Refrigerant leaks
Formicary corrosion or pinholes in the tubes, often found after repeated recharges.
Damaged fins
Fins crushed or corroded beyond cleaning.
A refrigerant change
System changes during the shift to lower-GWP refrigerants.
Poor capacity or icing
Uneven feed from a damaged distributor or feeder tubes.
What we confirm before we quote
You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

- AFin height
- Finned area inside the casing.
- BFin length
- Finned length between tube sheets.
- Rows and fins per inch
- Rows deep and fin spacing.
- Refrigerant
- The refrigerant in the system now. With the move to A2L refrigerants such as R-454B and R-32, we confirm the coil suits your system.
- Circuiting
- Single circuit, face split, row split or intertwined, matched to the number of compressor circuits.
- JDistributor and suction
- Distributor and nozzle, number of feeder tubes, suction connection size and location.
- H, ICasing and overall size
- Casing depth, flanges and overall length.
- Performance
- Airflow, entering air dry bulb and wet bulb, and suction temperature.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.

Construction notes
A DX coil and its condensing unit are a matched pair. When the coil was originally selected by the equipment manufacturer, we use the unit model and capacity to size the replacement so the system balances.
If the coil sits inside a packaged unit, access matters as much as fit. Tell us how the coil comes out of the cabinet; it can affect how the replacement is built.
Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.
Frequently asked questions
What information is needed to match a replacement DX coil?
Fin height and fin length, rows and fins per inch, the refrigerant, the circuiting, the distributor and suction connections, and the casing size. The condensing unit model and capacity help us size the coil so the system balances.
Do you need to know the refrigerant?
Yes. It is on the condensing unit nameplate. With the move to A2L refrigerants, we confirm the coil suits the refrigerant in your system now.
Can you match the distributor?
Send photos of the distributor, nozzle and feeder tubes. We match the circuiting and size the distributor for your capacity and refrigerant.
Can you replace just the evaporator in a rooftop unit?
In many units, yes, when the coil can come out through the cabinet panels. Some packaged units are better served by the equipment manufacturer, and we will say so.
How quickly can a DX coil ship?
Typical production is 10 to 15 days standard, 5 days expedited and 2 days emergency, where the coil design and the plant schedule allow. Production times are set by the build plant and vary with its capacity, so your quote confirms them. Freight is quoted separately.

Replacing a DX coil?
Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.