Hot water coil replacement
Replacement hot water heating coils for air handlers, preheat and reheat positions and built-up systems. We match the size, connections and hand of the coil you have and confirm it will deliver the heat you need. For small duct-mounted reheat coils, see hot water booster coils.


When it is time to replace
Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.
Freeze damage
Split tubes or bulged return bends after a cold snap, the most common failure on preheat coils that see outside air.
Leaks
Pinhole leaks from erosion or corrosion, often near the headers or return bends.
Not enough heat
Scaled tubes, or a coil that was undersized for the space or for lower supply water temperatures.
A renovation or load change
New airflow or a change in hot water temperatures, for example after a boiler or heat pump upgrade.
What we confirm before we quote
You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

- AFin height
- The finned area air passes through, measured inside the casing.
- BFin length
- Finned length between the tube sheets, not the overall length.
- Rows and fins per inch
- Heating coils are often one or two rows; fins counted over one inch.
- Tube size and circuiting
- Usually 1/2 in. or 5/8 in. tube, and the number of tubes fed by the supply header.
- JConnections
- Size, type (male or female pipe thread, or sweat) and location; same-end or opposite-end.
- Hand
- Left or right hand, judged from the entering-air side. See the handing guide.
- H, ICasing and overall size
- Casing depth, flanges and overall length.
- Performance
- Airflow, entering air temperature, entering and leaving water temperatures or flow, and glycol percentage.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.

Construction notes
Most commercial hot water coils use seamless copper tube expanded into aluminum fins in a galvanized steel casing. Heating coils are usually shallower than cooling coils, often one or two rows.
A preheat coil that froze will freeze again unless something changes. Glycol, a circulating pump on the coil, freezestat placement and how the coil drains all matter, and we will ask about them before quoting a like-for-like replacement.
Lower supply water temperatures, common after boiler or heat pump upgrades, reduce the output of an existing coil. We size the replacement for the water temperatures you run now.
Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.
Frequently asked questions
How do I size a replacement hot water or glycol coil for an existing system?
Send the airflow, entering air temperature, the entering and leaving water temperatures or flow, and the glycol percentage. We size the replacement for the water temperatures you run now, not the ones the original was selected for.
What measurements are needed to order a replacement hot water coil?
Fin height and fin length inside the casing, rows and fins per inch, tube size, connection size, type and location, hand, and the casing depth and overall length.
Why did my hot water coil freeze?
Usually outside air below freezing reached a coil with no flow, or flow too low to keep it warm. Pump, glycol and control changes stop it happening again; a new coil alone will not.
Can the replacement have more rows than the original?
Often, if the casing depth allows and the fan can handle the extra air pressure drop. We check both before suggesting it.
Will the new coil line up with my piping?
That is the aim. We match connection size, type and location to the piping as it is today, and tell you before ordering if anything has to change.

Replacing a hot water coil?
Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.