
Steam distribution coil replacement
A steam distribution coil, also called a steam distributing or non-freeze coil, carries steam through an inner tube with small orifices that spread it evenly along the length of the outer condensing tube. That even heating and positive drainage make it the usual choice where entering air can drop below freezing.


When it is time to replace
Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.
Repeated freeze failures
A standard steam coil in an outside air or preheat position that keeps splitting.
Uneven leaving air
Stratified discharge air across a long coil face.
Long coils
Coil lengths where steam has trouble reaching the far end of a standard coil.
End of service life
Corroded casing, failed inner tubes or leaking headers on an older steam distribution coil.
What we confirm before we quote
You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

- AFin height
- Finned area inside the casing.
- BFin length
- Finned length; very long coils may need steam supplied from both ends.
- Tube construction
- Outer tube size, usually 1 in. nominal, and whether it is one row or two.
- JConnections
- Supply and condensate size, type and location; same-end or opposite-end.
- Steam pressure and control
- Operating pressure, and whether the coil is modulated by a control valve.
- Pitch
- Steam distribution coils are pitched toward the condensate connection; we match the orientation.
- H, ICasing and overall size
- Casing depth, flanges and overall length.
- Performance
- Airflow, entering air temperature, required leaving air temperature.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.

Construction notes
Steam distribution coils are not freeze-proof, whatever the name suggests. With low steam pressure from a modulating valve, condensate can still back up if the coil is not vented and trapped properly. We will ask how the coil is piped and controlled before we size the replacement.
Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.
Frequently asked questions
What should I consider when replacing a steam coil used for outside-air preheat?
Whether entering air drops below freezing, the steam pressure, and how the coil is piped, trapped, vented and controlled. Where a standard steam coil keeps freezing, a steam distribution coil is the usual replacement.
Is a steam distribution coil the same as a non-freeze coil?
The names are used for the same tube-in-tube design. “Non-freeze” describes the intent, not a promise: trapping, venting and controls still decide whether condensate drains.
Can a steam distribution coil replace a standard steam coil?
Often, if the casing depth allows and the piping can be adapted. It is a common change where a standard steam coil has frozen.
Do long coils need steam from both ends?
Very long coils can. We check the length and steam pressure and tell you if the supply arrangement should change.
How do I measure a steam distribution coil?
Fin height and fin length, the outer tube size and number of rows, the supply and condensate connections, the pitch, and the casing depth and overall length. Photograph the fin face and both ends.

Replacing a steam distribution coil?
Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.


