Hot water booster coil replacement
Booster coils are the small hot water coils mounted in ductwork and on VAV terminals to reheat air for a zone. They are simple, but there are a lot of them, and a building often needs several replaced at once.


When it is time to replace
Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.
Leaking reheat coils
Water at ceiling tiles below a VAV box.
Cold zones
A zone that cannot reach setpoint with hot water flowing.
Freeze damage
Split tubes in coils near outside air.
Renovation
New ductwork or terminal units that need matching coils.
What we confirm before we quote
You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

- AFin height
- Finned height inside the casing.
- BFin length
- Finned width across the duct.
- Rows
- Usually one or two rows.
- Duct connection
- Slip-and-drive or flanged casing, and the duct size it fits.
- JConnections
- Size, type and location; booster coils are usually same-end connected.
- Hand and airflow direction
- Which side the piping is on, viewed from the entering air side.
- Performance
- Airflow, entering air and water temperatures, and flow if known.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.

Construction notes
When you are replacing several booster coils, send a list with each tag, size and location. We quote them together and keep the tags on the paperwork so the right coil goes to the right box.
Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.
Frequently asked questions
Can you quote a whole building’s booster coils at once?
Yes. Send a list with each tag, size and location, and we quote them together with the tags on the paperwork.
Slip-and-drive or flanged?
Match the duct connection you have now. Slip-and-drive is common on VAV reheat coils.
One row or two?
Match the original unless the zone has been short of heat; then a second row may help, if the airflow allows.
What measurements does a booster coil need?
Finned height and width, rows, the duct connection and duct size, the connection size, type and location, and which side the piping is on, viewed from the entering air side.

Replacing a booster coil?
Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.