Split and sectional replacement coils

Sometimes the original coil went in before the walls did. A sectional replacement is built as two or more smaller coils so it can be carried through existing doors and openings and assembled in the unit, without cutting walls or roofs.

Coil shop technician brazing return bends, wearing protective gear

When it is time to replace

Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.

  • The coil cannot come out in one piece

    The old coil is bigger than any door or opening on the way out.

  • Access would mean demolition

    Getting a full-size coil in would mean cutting a wall, roof or unit casing.

  • Rigging costs

    A crane or major rigging just to move one coil.

  • Built-up units

    Large field-built air handlers with stacked coils.

What we confirm before we quote

You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

Coil shop technician brazing return bends, wearing protective gear
AFin height
Of the original coil, inside the casing.
BFin length
Finned length between tube sheets.
The way in
The smallest door, chase or elevator along the path, with height, width and any turns.
Unit section
The opening in the unit and the support rails the sections sit on.
JConnections
Where the piping is now. Each section has its own headers, so the piping is adjusted on site.
Hand
Left or right hand, from the entering-air side.
Performance
Airflow, temperatures and fluid, so the sections together meet the original duty.

Request a quote Measuring worksheets

Built in America.
Rated. Tested.

Flag of the United States

Built in American plants

Our manufacturing partners’ plants are located in:

  • Oklahoma City, OK
  • Okarche, OK
  • Moscow, TN
  • Phoenix, AZ
  • Tampa Bay, FL
  • Fort Worth, TX
AHRI Certified

AHRI 410 rated selections

Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.

100%Leak tested

Leak tested under water

Every coil is pressurized and leak tested under water before it leaves the plant.

Copper hairpin tubes being laced through aluminum fins on a coil line

Construction notes

Splitting a coil adds connections. Each section has its own headers, and we lay the sections out so the connections land where your piping can reach them.

The sections are selected so that together they meet the original duty, with the same face area, rows and fin spacing wherever the space allows.

Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.

Frequently asked questions

How small can the sections be?

That depends on the coil and the way in. Send the smallest opening on the path and we work back from it.

Does a sectional coil change the piping?

Each section has its own headers, so there are more connections and the piping is adjusted on site. We lay the sections out so the connections land where your piping can reach them.

Will the sections match the original capacity?

The sections are selected so that together they meet the original duty, with the same face area, rows and fin spacing wherever the space allows.

What do you need to quote a sectional coil?

The original coil’s fin height and length, the smallest door, chase or elevator along the path, the unit section opening and rails, the connections, the hand and the operating conditions.

Replacing a sectional coil?

Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.