Chilled water coil replacement

Replacement chilled water coils and glycol cooling coils for air handlers, fan coils and built-up systems. We match the size, connections and hand of the coil you have, then confirm the new one will deliver the cooling and dehumidification you need. Replacing a heating coil? See hot water coils.

Chilled or hot water coil with copper headers
Copper return bends stacked along a coil end

When it is time to replace

Not sure whether to repair or replace? Send photos of the damage and we will give you a straight opinion.

  • Leaks you keep chasing

    Pinhole leaks from erosion or corrosion, often near the headers or return bends.

  • Freeze damage

    Split tubes after a cold snap, usually on coils that see outside air or sit in a unit that was not drained for winter.

  • Lost capacity

    Fouled or corroded fins that cleaning no longer brings back, and spaces that will not hold temperature or humidity.

  • Corroded casing or drain pan

    Rust and water carryover where condensate has sat for years.

What we confirm before we quote

You do not need all of this to start. Send what you have and we will help with the rest, by phone, by photo or with an onsite visit in the Upper Midwest.

Chilled or hot water coil with copper headers
AFin height
The finned area air passes through, measured inside the casing.
BFin length
Finned length between the tube sheets, not the overall length.
Rows and fins per inch
Rows deep in the direction of airflow; fins counted over one inch. Cooling coils are often four to eight rows.
Tube size and circuiting
Usually 1/2 in. or 5/8 in. tube. The number of tubes fed by the supply header sets the circuiting.
JConnections
Size, type (male or female pipe thread, or sweat) and location; same-end or opposite-end.
Hand
Left or right hand, judged from the entering-air side. See the handing guide.
H, ICasing and overall size
Casing depth, flanges and overall length, so the coil fits the opening and lines up with your piping.
Performance
Airflow, entering air dry bulb and wet bulb, entering and leaving water temperatures or flow, and glycol percentage.

Request a quote Measuring worksheets

Built in America.
Rated. Tested.

Flag of the United States

Built in American plants

Our manufacturing partners’ plants are located in:

  • Oklahoma City, OK
  • Okarche, OK
  • Moscow, TN
  • Phoenix, AZ
  • Tampa Bay, FL
  • Fort Worth, TX
AHRI Certified

AHRI 410 rated selections

Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.

100%Leak tested

Leak tested under water

Every coil is pressurized and leak tested under water before it leaves the plant.

Copper hairpin tubes being laced through aluminum fins on a coil line

Construction notes

Most commercial chilled water coils use seamless copper tube expanded into aluminum fins, inside a galvanized steel casing with flanges for mounting. Copper fins and stainless steel casings are common upgrades where the air is corrosive or the coil sees washdown.

A cooling coil removes moisture as well as heat. Fin spacing, rows and face velocity decide how much it dehumidifies and whether condensate is carried off the coil into the duct, so we check both the leaving air temperature and the moisture load.

Glycol changes capacity. A coil selected for plain water and filled with a 30 to 50 percent glycol mix delivers less, so we rerun the selection with your actual fluid.

Every coil we supply is built to order by an established coil manufacturer and ships direct from the plant. Coils within the scope of AHRI Standard 410 can be supplied with the manufacturer’s certified performance rating; ask us to confirm for your coil.

Frequently asked questions

What should I look for in a replacement chilled water coil?

The same face size, rows, fin spacing, connections and hand as the coil you have, checked against your airflow, entering air conditions and water temperatures. A cooling coil also removes moisture, so we check the leaving air and the moisture load, not just the size.

What measurements are needed to order a replacement water coil?

Fin height and fin length inside the casing, rows and fins per inch, tube size, connection size, type and location, hand, and the casing depth and overall length. Airflow and water temperatures or flow let us check the capacity.

How does glycol concentration affect the capacity of a replacement chilled water coil?

A coil selected for plain water and filled with a 30 to 50 percent glycol mix delivers less. Tell us the glycol percentage and we rerun the selection with your actual fluid.

Do I need the original coil’s capacity?

No. Airflow, entering air temperature and the water temperatures or flow are enough to check a selection. If you have the original schedule or submittal, send it too.

Can the replacement have more rows than the original?

Often, if the casing depth allows and the fan can handle the extra air pressure drop. We check both before suggesting it.

Will the new coil line up with my piping?

That is the aim. We match connection size, type and location to the piping as it is today, and tell you before ordering if anything has to change.

Replacing a chilled water coil?

Send the nameplate, photos of the coil face and both ends, and any measurements you have. We will tell you what else we need.