Replacement coils for AAON equipment
AAON rooftop units and air handlers are built semi-custom, so two units with similar model numbers can carry different coils. We match the replacement to the coil actually in your unit, and tell you plainly when AAON is the better source.
Compatible, not genuine OEMMidwest Coils supplies replacement coils built to fit and perform in AAON equipment. They are not AAON parts, are not made or authorized by AAON, and Midwest Coils is not affiliated with or endorsed by AAON. AAON is a trademark of its owner, used here only to identify the equipment.

Common equipment
Packaged rooftop units
DX evaporator coils and heating coils in rooftop equipment such as the RN and RQ series. Some rooftop units are set up as air handlers with chilled water or hot water coils.
Indoor and outdoor air handlers
Chilled water, hot water, steam and DX coils in AAON air handling units.
Reheat and heating coils
Hot water and steam heating coils, and reheat coils used for humidity control.
What to send us

- Unit nameplate
- Full model and serial number. AAON model numbers are long because they describe the unit’s options; send the whole string.
- Coil construction
- Whether the coil is copper tube with aluminum fins or a microchannel design. A close-up photo of the tube ends answers this.
- Coil photos
- The fin face straight on, the header end with connections, and the return bend end.
- Access
- Which panels open and how the coil comes out of the cabinet.
No readable tag? Measurements and photos are enough to start. How to measure a coil

AAON lines we match.
Every coil is built to order, so the age of the unit does not matter. These are the AAON lines we see most often. If yours is not listed, send the nameplate.
RN Series rooftop units
Evaporator, hot water, steam and reheat coils.
RQ Series rooftop units
Smaller packaged units.
RZ Series rooftop units
Large-tonnage rooftops.
RK, RL and RM rooftop units
Older AAON rooftops still common in the field.
H3 and V3 air handlers
Horizontal and vertical indoor air handlers: chilled water, hot water and DX coils.

What we review
Because AAON units are configured to order, we confirm the coil from photos and measurements rather than relying on the model number alone. For DX coils we match circuiting to the compressor arrangement and confirm the refrigerant.
How matching works
- We identify the coil from the nameplate, photos and measurements, and ask for anything missing.
- We specify a replacement to the same face size, rows, fin spacing, connections and hand, and check its performance against your airflow and temperatures.
- You approve a drawing and quote before anything is built.
- The coil is built to order by one of our manufacturing partners and ships direct to your site.
Limitations
Air-cooled AAON rooftop units commonly use microchannel condenser coils. For some of those, a replacement through the equipment manufacturer is the better route, and we will tell you so.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.
Other equipment we match.
Built to fit air handlers, rooftop units and fan coils from the major manufacturers. Send the nameplate and we match the rest: size, rows, connections, hand and capacity.
Compatible replacements, not genuine OEM parts. Midwest Coils is not affiliated with or endorsed by these manufacturers.
Frequently asked questions
Can you replace a coil in AAON equipment?
Yes. Replacement coils are built to order to fit AAON air handlers, rooftop units and other commercial equipment, matched from the nameplate, the existing coil and your measurements. They are compatible replacements, not genuine OEM parts.
What do you need to match a AAON replacement coil?
The full model and serial number from the unit nameplate, any tag on the coil itself, and photos of the fin face, the header end and the return bend end. Fin height, fin length, rows and connection sizes help firm up the quote.
Does the age of the AAON unit matter?
No. Every coil is built to order, so units long out of production are not a dead end. If the nameplate is unreadable, measurements and photos are enough to start.
Which AAON lines do you match?
RN, RQ and RZ rooftop units, older RK, RL and RM units, and H3 and V3 air handlers, among others.
Why do AAON coils need photos and measurements?
AAON units are configured to order, so two units with similar model numbers can carry different coils. We confirm the coil from photos and measurements rather than the model number alone.
How quickly can the coil ship?
Typical production is 10 to 15 days standard, 5 days expedited and 2 days emergency, where the coil design and the plant schedule allow. Production times are set by the build plant and vary with its capacity, so your quote confirms them. Freight is quoted separately.

Send the AAON nameplate and a few photos.
That is usually enough to start. We will tell you what else we need and quote the replacement.