Replacement coils for Rheem and Ruud equipment
Rheem and Ruud are sister brands, and their commercial equipment is mostly packaged rooftop units and split systems. Replacement usually means an evaporator coil that leaks or a condenser coil that has corroded. We match the coil to the unit and tell you plainly when the equipment manufacturer is the better source.
Compatible, not genuine OEMMidwest Coils supplies replacement coils built to fit and perform in Rheem and Ruud equipment. They are not Rheem or Ruud parts, are not made or authorized by Rheem or Ruud, and Midwest Coils is not affiliated with or endorsed by Rheem or Ruud. Rheem and Ruud are trademarks of their owners, used here only to identify the equipment.

Common equipment
Packaged rooftop units
DX evaporator and condenser coils in commercial packaged units, including the Renaissance line.
Commercial split systems
Split-system air handlers and condensing units.
Field-added heating coils
Duct-mounted hot water or steam coils installed downstream of the unit, which we treat like any other water or steam coil.
What to send us

- Unit nameplate
- Model and serial number from the unit nameplate, usually on the cabinet near the electrical access panel.
- Coil construction
- Whether the coil is copper tube with aluminum fins or an all-aluminum or microchannel design. A close-up photo of the tube ends answers this.
- Refrigerant
- The refrigerant listed on the nameplate and anything changed since.
- Access
- How the coil comes out of the cabinet: which panels open and whether the unit must be partly dismantled.
No readable tag? Measurements and photos are enough to start. How to measure a coil

Rheem lines we match.
Every coil is built to order, so the age of the unit does not matter. These are the Rheem lines we see most often. If yours is not listed, send the nameplate.
Rheem Renaissance rooftop units
Evaporator and condenser coils in commercial packaged units.
Rheem Classic commercial packaged units
Light commercial rooftops.
Ruud Achiever rooftop units
Evaporator and condenser coils.
Commercial split systems
Split-system air handler and condensing unit coils.

What we review
Rooftop coil replacements usually hinge on access and circuiting. We confirm the coil can be installed through the available panels, that circuiting matches the compressor arrangement, and whether a coating makes sense if the original coil corroded.
How matching works
- We identify the coil from the nameplate, photos and measurements, and ask for anything missing.
- We specify a replacement to the same face size, rows, fin spacing, connections and hand, and check its performance against your airflow and temperatures.
- You approve a drawing and quote before anything is built.
- The coil is built to order by one of our manufacturing partners and ships direct to your site.
Limitations
Many newer packaged units use microchannel or all-aluminum coils that are specific to the unit. For some of those, a replacement through the equipment manufacturer is the better route, and we will tell you so.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.
Other equipment we match.
Built to fit air handlers, rooftop units and fan coils from the major manufacturers. Send the nameplate and we match the rest: size, rows, connections, hand and capacity.
Compatible replacements, not genuine OEM parts. Midwest Coils is not affiliated with or endorsed by these manufacturers.
Frequently asked questions
Can you replace a coil in Rheem and Ruud equipment?
Yes. Replacement coils are built to order to fit Rheem and Ruud air handlers, rooftop units and other commercial equipment, matched from the nameplate, the existing coil and your measurements. They are compatible replacements, not genuine OEM parts.
What do you need to match a Rheem and Ruud replacement coil?
The full model and serial number from the unit nameplate, any tag on the coil itself, and photos of the fin face, the header end and the return bend end. Fin height, fin length, rows and connection sizes help firm up the quote.
Does the age of the Rheem and Ruud unit matter?
No. Every coil is built to order, so units long out of production are not a dead end. If the nameplate is unreadable, measurements and photos are enough to start.
Which Rheem and Ruud lines do you match?
Rheem Renaissance and Classic commercial packaged units, Ruud Achiever rooftop units and commercial split systems, among others.
How quickly can the coil ship?
Typical production is 10 to 15 days standard, 5 days expedited and 2 days emergency, where the coil design and the plant schedule allow. Production times are set by the build plant and vary with its capacity, so your quote confirms them. Freight is quoted separately.
What if I only have photos and measurements?
Send the measurements and photos. We return a dimensioned drawing and a quote, and you check the drawing against the unit before anything is built. Confirming it fits is your call, so nothing is released until you approve it.

Send the Rheem or Ruud nameplate and a few photos.
That is usually enough to start. We will tell you what else we need and quote the replacement.