Replacement coils for York and Johnson Controls equipment
York equipment, now sold by Johnson Controls, is common in offices, schools and hospitals, from semi-custom air handlers to packaged rooftop units. We match replacement coils to the unit using the nameplate, the coil itself and your measurements.
Compatible, not genuine OEMMidwest Coils supplies replacement coils built to fit and perform in York and Johnson Controls equipment. They are not York or Johnson Controls parts, are not made or authorized by York or Johnson Controls, and Midwest Coils is not affiliated with or endorsed by York or Johnson Controls. York and Johnson Controls are trademarks of their owners, used here only to identify the equipment.

Common equipment
Semi-custom and custom air handlers
Indoor and outdoor air handlers such as the York Solution line, with chilled water, hot water, steam and DX coils.
Rooftop units
DX evaporator and condenser coils in packaged rooftop equipment, from light commercial units to large-tonnage rooftops.
Fan coils and split systems
Smaller water and DX coils, often replaced in batches.
What to send us

- Unit nameplate
- Full model and serial number. On air handlers it is usually on the casing near the fan or access section.
- Coil tag
- Some coil sections carry their own tag on the casing or near the headers. Photograph it if you find one.
- Coil photos
- The fin face straight on, the header end with connections, and the return bend end.
- Piping and clearances
- Where the supply and return pipes enter, and how much room there is to pull the old coil.
No readable tag? Measurements and photos are enough to start. How to measure a coil

York lines we match.
Every coil is built to order, so the age of the unit does not matter. These are the York lines we see most often. If yours is not listed, send the nameplate.
York Solution air handlers
Including XT indoor and outdoor units: chilled water, hot water, steam and DX coils.
York custom air handlers
Built-to-order air handlers with water, steam and DX coils.
Sunline rooftop units
Light commercial packaged units: evaporator and condenser coils.
Predator rooftop units
Packaged rooftops: evaporator and condenser coils.
Series 20, 40 and 100 rooftop units
Mid-size and large-tonnage rooftops.

What we review
With York air handlers we check how the coil sits in its section, the casing flanges and drain pan clearances, and whether stacked coils share a header arrangement. For DX coils we match circuiting to the condensing section and confirm the refrigerant now in the system.
How matching works
- We identify the coil from the nameplate, photos and measurements, and ask for anything missing.
- We specify a replacement to the same face size, rows, fin spacing, connections and hand, and check its performance against your airflow and temperatures.
- You approve a drawing and quote before anything is built.
- The coil is built to order by one of our manufacturing partners and ships direct to your site.
Limitations
Replacement coils are matched to fit and perform in the unit. Features tied to the original coil, such as integral drain pans or factory controls, stay with the unit and are not part of the coil we supply.

Built in America.
Rated. Tested.
Built in American plants
Our manufacturing partners’ plants are located in:
- Oklahoma City, OK
- Okarche, OK
- Moscow, TN
- Phoenix, AZ
- Tampa Bay, FL
- Fort Worth, TX

AHRI 410 rated selections
Coils within AHRI 410 scope can come with the manufacturer’s certified rating. Ask us to confirm for your coil.
Leak tested under water
Every coil is pressurized and leak tested under water before it leaves the plant.
Other equipment we match.
Built to fit air handlers, rooftop units and fan coils from the major manufacturers. Send the nameplate and we match the rest: size, rows, connections, hand and capacity.
Compatible replacements, not genuine OEM parts. Midwest Coils is not affiliated with or endorsed by these manufacturers.
Frequently asked questions
Can you replace a coil in York and Johnson Controls equipment?
Yes. Replacement coils are built to order to fit York and Johnson Controls air handlers, rooftop units and other commercial equipment, matched from the nameplate, the existing coil and your measurements. They are compatible replacements, not genuine OEM parts.
What do you need to match a York and Johnson Controls replacement coil?
The full model and serial number from the unit nameplate, any tag on the coil itself, and photos of the fin face, the header end and the return bend end. Fin height, fin length, rows and connection sizes help firm up the quote.
Does the age of the York and Johnson Controls unit matter?
No. Every coil is built to order, so units long out of production are not a dead end. If the nameplate is unreadable, measurements and photos are enough to start.
Which York lines do you match?
York Solution and custom air handlers, Sunline and Predator rooftop units, and Series 20, 40 and 100 rooftop units, among others.
How quickly can the coil ship?
Typical production is 10 to 15 days standard, 5 days expedited and 2 days emergency, where the coil design and the plant schedule allow. Production times are set by the build plant and vary with its capacity, so your quote confirms them. Freight is quoted separately.
What if I only have photos and measurements?
Send the measurements and photos. We return a dimensioned drawing and a quote, and you check the drawing against the unit before anything is built. Confirming it fits is your call, so nothing is released until you approve it.

Send the York or Johnson Controls nameplate and a few photos.
That is usually enough to start. We will tell you what else we need and quote the replacement.